Get more of Elevator World. Sign up for our free e-newsletter. NEC has a further note that the term wheelchair lift has been changed to platform lift.. The Americans with Disabilities Act Accessibility Guidelines for Buildings and Facilities (ADAAG) now require the cab to have a special phone accessible by individuals with disabilities. (Hard-service and junior hard-service are trade names that apply to over 30 types of flexible cord, all beginning with the letter S. They have varying properties, such as oil resistance, and various material compositions for insulation, such as a thermoplastic elastomer. Described below are several work practices that may be used to reduce arc-flash hazards when working on energized equipment: David Herres holds a New Hampshire Master Electricians license and has worked as an electrician in the northern part of that state for many years. The action you just performed triggered the security solution. My reasoning comes from 620.24 (A) and (C). The new ADAAG guidelines now require that emergency power be available to elevators that have four or more stories of travel above or below the accessible floor [4.1.3(9)(1)]. When you consider that an elevator is an enclosed room with one or more doors that people voluntarily enter so they may travel hundreds of feet up or down, several observations are in order. , !! But the lights don't have to be in the pit itself. Within cars, these additional wiring methods are permitted: The following additional wiring methods are permitted on the car assembly in lengths not exceeding 6 ft.: Within machine rooms, these additional wiring methods are permitted: The following wiring methods are permitted on the counterweight assembly in lengths not to exceed 6 ft.: Having looked at NEC 2011 mandates for elevator and related equipment installations, we will cover wiring methods, overcurrent protection, grounding and other related NEC provisions in part two of this series , running in the April 2012 issue of ELEVATOR WORLD. The electrical system designer calculates the maximum available fault current at the elevator controller. Feeders may be installed within the hoistway where the elevator has a driving-machine motor in the hoistway or on the car or counterweight. Pit drainage must be designed to eliminate a minimum capacity of 3,000 gallons per hour (or 50 GPM) per elevator car. Hazards created by water, snow or condensation in the work area can cause slips, falls and accidental contact. The basic requirement is for minimum clear distances of various depths for equipment operating at 600 V or less, nominal, depending upon voltage to ground and lateral distance to insulated or grounded surfaces or exposed live parts (not an issue in elevator machine rooms).
GFCIs in Elevator Pits, Receptacles and More NEC Article 620 Part VI, Disconnecting Means and Control, is rather exacting. These are: remote machine room and control room (for elevator and dumbwaiter), and remote machinery space and control space (for elevator and dumbwaiter). Years may lapse between the design and installation stages of a project. (f) Illumination of Pits. The hazards are external to the equipment enclosure since equipment SCCR testing and evaluation criteria for product standards are most often performed with the enclosure doors closed and latched, and the fault occurring external to the enclosure. This device must be either a fused disconnect or a circuit breaker because ANSI/ASME A17.1 requires you to install an additional overcurrent protection device (OCPD) in the elevator equipment room. Where a feeder powers more than one elevator, you need selective coordination; the OCPDs must be series-designed so a fault at one of the elevators will be cleared by only the OCPD serving it. David Herres Generally, it is decreed that the supply voltage is not to exceed 300 V between conductors (allowing for the familiar 240-V concept), although there are exceptions.
PDF Elevator Acceptance Inspections - Tennessee The traveling cable, of necessity, is exempted. Such design innovations require sophisticated wiring strategies. Jul 15, 2021. This position paper is written to provide guidance to members whose employees are engaged in elevator-industry work that might expose them to arc-flash hazards, and to assist members in complying with applicable OSHA and National Fire Protection Association (NFPA) standards. If it kills the son of the owner, the son of that builder shall be put to death.. With heavy use on a hot day, the oil can overheat, causing elevator shutdown. Installing electrical equipment where its SCCR is less than the available short-circuit current creates serious safety hazards. But, building codes had been in existence for many centuries. (C) Duplex Receptacle. A further requirement concerns elevator-car air-conditioning and heating. The proposals resulted in adding new requirements in the 2017 NEC for: This article will also discuss other Code requirements that include selective coordination for elevators that are supplied by emergency, legally required standby or critical operation power systems or multiple elevators supplied from a single feeder, and shunt tripping of elevators where the elevator equipment room and/or shaft has a fire suppression sprinkler system. -inch conduit is needed to the sump pump. If you can illuminate the pit using lights that are "above the top of the pit" (whatever that . endstream
endobj
954 0 obj
<. NEC Article 620 covers elevators, dumbwaiters, escalators, moving walks, platform lifts and stairway chairlifts. Cross-sectional areas of conduits are given in Chapter 9, Table 4. NEC Article 620 Part IV, Installation of Conductors, contains key mandates for elevator wiring. Where the elevator shaft and/or equipment room has a sprinkler fire suppression system installed, the elevator Code requires main line power to the elevator be removed prior to the application of water. Your IP: Mike Holt. Section 620.43, Location of and Protection for Cables, provides that traveling cable supports are to be located so as to reduce the possibility of damage due to the cables coming in contact with the hoistway construction or equipment in the hoistway to a minimum. You'll need to run telephone cables to the equipment room control panel, but the elevator supplier will take care of getting the cables to the elevator cab. You must run a separate insulated grounding conductor with the feeder conductors from the electrical source to the elevator controller. This is the area within the hoistway beneath the car, and there are occasions when elevator technicians have to work in this area for maintenance and troubleshooting. Proper selective coordination in a multi-elevator installation on the same feeder ensures if one elevator develops a fault, the other units will not be shut down. Luminaires must be lensed or equipped with wire guards to protect the lamps. In a time when increasing value is placed on even small amounts of real estate, elevator design must strive to configure, efficiently control and drive elements to whatever degree possible, and that is the thinking behind some alternate locations for these structures. Corporate Office If the entire feeder/branch circuit assembly were to be protected in the conventional manner, the motor would cut out long before reaching operating speed. Hard-service cords are permitted only as flexible connections for the top-of-car operating device or the car-top work light.
Your Quick and Easy Elevator Code Checklist | Kings III from the exposed components, and the incident energy calculated at 18 in. Furthermore, at least one 125-V, single-phase, 15- or 20-amp duplex receptacle is to be provided in each machine room or similar location. hbbd```b``+3dL
`Y[gw9`RLJO*A$w$@L`F*{|0 P
Hydraulic elevator pit | Electrician Talk This may be countered by providing good machine-room ventilation. You are a subscriber that needs to Sign In.
Many people use portable generators until power is restored. The many codes and guidelines that regulate the electrical design of an elevator can seem overwhelming, and dealing with the electrical inspector, elevator inspector, and Fire Marshal can be even more intimidating. If your specifications require a vent at the top of the shaft for venting smoke, you must provide a key switch with a pilot light to control that vent. NEC specifies Hoistway wiring, and doesn't seem to distinguish between hoistway and pit. tC|[S9G?+uJP>&/TOy o PK ! The basic wiring methods are rigid-metal, rigid nonmetallic or intermediate-metal conduit; electrical metallic or rigid nonmetallic tubing; wireways; or Type MC, MI or AC cable, unless otherwise permitted. The proposals resulted in adding new requirements in the 2017 NEC for: Marking the elevator controller short-circuit current rating (SCCR) by the elevator control-ler manufacturer. Modern electronic elevator controls can be sensitive to temperature shifts. This strategy works to improve the flexibility of the traveling cable, but it is contrary to a general NEC rule concerning the paralleling of conductors, which is generally done in very large sizes to avoid unwieldy wire pulls and terminations. The code is not concerned with the efficiency or sophistication of equipment that it covers, except insofar as safety (in terms of human injury and property damage) is concerned. The article stands apart from the rest of the code in the sense it exempts these categories of circuits from the general requirements for wiring in most occupancies, found in Chapter 3. These are the individual branch circuits required for car lighting, receptacles, auxiliary lighting and ventilation on each elevator car; individual branch circuits for machine-room and similar location lighting and receptacle; and branch circuits for hoistway pit lighting and receptacle(s). Feeder and branch-circuit conductors are required to have specified ampacities: Feeder conductors of less ampacity are permitted for group installations and quite common in elevator work. In this case, it may be best if the elevator controller manufacturer does not include the elevator disconnecting means (often offered as a circuit breaker) but instead have the installer provide a separate fused disconnect to comply with NEC 620.51(A) and also achieve a high SCCR for the elevator controller when fuses are provided as specified by the elevator controller and marked on the elevator controller nameplate. An example would be the elevator, as well as all wiring in a utility-owned administration building. ranged from 0.06 cal/cm2 to 0.95 cal/cm2, which indicates that the arc-flash hazard to employees is primarily to the hands and arms. NEC 620.62 requires the elevator disconnecting means (fused switch or circuit breaker) to selectively coordinate with all supply-side overcurrent devices. The demand factors are given in Table 620.14, which allows significant reductions as the number of motors is increased. Though I understand how someone might argue two. Supports for cables or raceways in a hoistway or in an escalator or moving-walk wellway or platform lift and stairway chairlift runway must be securely fastened to the guide rail, escalator or moving-walk truss, or to the hoistway, wellway or runway construction.